Please enable JavaScript to view this site.

Manual InterForm400 English 2023

If you want to test the functionality of the AFC definitions for an output queue, you can use the option 13=Enter step by step mode:

 

         Work with Auto Forms Control output queues                   AFC300D  

                                                                               

Position to . . . . . .                           Outq                        

                                                                               

Type options, press Enter.                                                    

  2=Change   3=Copy   4=Delete   5=Display   8=Start AFC-job   9=End AFC-job  

  12=Work with output queue   13=Enter step by step mode                    

                                                                               

Opt  Outq        Library     Description                               Status  

  AFC_INPUT1  APF3812     Job for sample printout                   *ACTIVE

 

 

In order to use this option the AFC job must be active.

 

After running this option you will get a break message in the current job and the AFC job will stop and wait for an answer, before executing each sequence line, when a spooled file arrives. The message will look like this:

 

                              Display Messages                                

                                                      System:   INTER03        

Queue . . . . . :   QPADEV0009              Program . . . . :   *DSPMSG        

  Library . . . :     QSYS                    Library . . . :                  

Severity  . . . :   00                      Delivery  . . . :   *BREAK        

                                                                               

Type reply (if required), press Enter.                                        

  AFC-job AFC_INPUT1/AFCOPER/203661 is ready to continue with seqnbr 1 from    

    AFC-queue AFC_INPUT1.  (G *ENDDBG)                                        

    Reply . . .   ___________________________________________________________  

                                                                               

                                                                               

                                                                               

                                                                               

                                                                               

                                                                               

                                                                               

                                                                               

                                                                               

                                                                               

                                                                        Bottom

F3=Exit              F11=Remove a message                 F12=Cancel          

F13=Remove all       F16=Remove all except unanswered     F24=More keys        

 

                                                                               

You can now check the output queue and the spooled files generated so far, before you answer the message with ā€˜Gā€™ (for Go) and let the AFC job execute this single sequence line. When you tested enough and what the job to return to normal execution, you answer the message with *ENDDBG (end debug) or end and restart the AFC job.