This is the list of PTFs, that are available for InterForm400.
Please notice:
•All PTFs are created for an interval of versions. Versions, that are newer than the highest version already includes the changes in the PTF.
•If you want to install more than one PTF in InterForm400, then you need to install the PTFs in numeric order, starting with the PTF with the lowest number.
•The link for download of the PTF is found on the left in blue.
•The procedure to install a PTF is covered in this section.
The PTFs are listed in sections for each year version:
PTF number |
Description |
From version |
To version |
OS400 |
Module |
---|---|---|---|---|---|
PDF filenaming: 32nd variable not transferred to Closing Exit program (parm list 3) and PDF filenaming: Subfile error: First line/position is repeated for all variables |
2023.M01 |
2023.M02 |
V7R2M0 |
||
Spooled file selection does not work |
2023.M01 |
2023.M02 |
V7R2M0 |
||
Empty "Reply-to" if run in batch |
2023.M01 |
2023.M02 |
V7R2M0 |
||
Decimal-data error in APF700PCL in old behaivour. |
2023.M01 |
2023.M02 |
V7R2M0 |
||
QR-Code in ZPL output is missing or contains empty data |
2023.M01 |
2023.M01 |
V7R2M0 |
||
Extract IF400 config and Trace (2023) Reissue (Sets SYSLOGP max membersize to *NOMAX, if exist) |
2023.M01 |
2023.M01 |
V7R2M0 |
||
QR-Code in PCL output gets wrong, almost empty. |
2023.M01 |
2023.M01 |
V7R2M0 |
||
Extract IF400 config and Trace (2023) |
2023.M01 |
2023.M01 |
V7R2M0 |
||
Decimal-data error in PCL |
2023.M01 |
2023.M01 |
V7R2M0 |
||
Ressource busy getting .eml file |
2023.M01 |
2023.M01 |
V7R2M0 |
||
User ESC char not processed in QR |
2023.M01 |
2023.M01 |
V7R2M0 |
||
Running JVM now set to output=*NONE. Install this PTF to avoid prints out of Java logs. |
2023.M01 |
2023.M01 |
V7R2M0 |
||
On the APF3812/PRTPDF command you can now add a user defined PJL. The user exit program is not called, as there are no spooled file attributes to pass to the exit program. |
2023.M01 |
2023.M01 |
V7R2M0 |
||
Swiss payment QR-code was using latin1 symbol set. It is changed to UTF8 with this PTF. |
2023.M01 |
2023.M01 |
V7R2M0 |
PTF number |
Description |
From version |
To version |
OS400 |
Module |
---|---|---|---|---|---|
Running JVM now set to output=*NONE. Install this PTF to avoid print out of Java logs. |
2022.M04 |
2022.M05 |
V7R2M0 |
||
On the APF3812/PRTPDF command you can now add a user defined PJL. The user exit program is not called, as there are no spooled file attributes to pass to the exit program. |
2022.M01 |
2022.M05 |
V7R2M0 |
||
OSC stops with an error while referring to a JC library. Removed debug information. |
2022.M01 |
2022.M05 |
V7R2M0 |
||
Swiss payment QR-code was using latin1 symbol set. It is changed to UTF8 with this PTF. |
2022.M01 |
2022.M05 |
V7R2M0 |
||
Call to QDCXLATE ended in error while called from program APF700PDF. |
2022.M01 |
2022.M05 |
V7R2M0 |
||
Missing content on backpage overlay for PCL print out. |
2022.M01 |
2022.M05 |
V7R2M0 |
||
Wrong placement of &&IMG image in PCL when overlay is rotated 090 or 270 degrees, and image is rotated 0 or 180 degrees. |
2022.M01 |
2022.M04 |
V7R2M0 |
||
Decimal data error while creating unicode PCL. |
2022.M01 |
2022.M04 |
V7R2M0 |
||
Remove internal usage of USRDFNDTA. |
2022.M01 |
2022.M04 |
V7R2M0 |
||
Reply-to should be empty, when set to *NONE. |
2022.M01 |
2022.M04 |
V7R2M0 |
||
Problem with *VAR copies in PDF. When copy management has a variable (*VAR) number of copies, the result will be wrong in PDF. |
2022.M01 |
2022.M04 |
V7R2M0 |
||
Running AFC-job prevented savlib of library APF3812. It is now possible to take backup of library APF3812 while subsystem, AUTO_FORM is running. But if a spooled file becomes ready in one of the output queues that are controlled by AUTO_FORM the AFC-job will fail. The subsystem AUTO_FORM must be closed and started again after the PTF has been installed. |
2022.M01 |
2022.M04 |
V7R2M0 |
||
Error in scanned Datamatrix barcode after large Datamatrix barcode. Error in scanned small Datamatrix barcode after large Datamatrix barcode, because of missing reinitializing of QC. |
2022.M01 |
2022.M03 |
V7R2M0 |
||
Missing concats in conditioned overlays in ZPL. Concat elements in conditioned overlays were not resolved and not shown in the ZPL output. With this PTF the concat elements in ZPL works as for PCL and PDF output. |
2022.M01 |
2022.M03 |
V7R2M0 |
||
Wrong special characters i unicode PDF. Special characters like 'Ä' are wrong when used in text in unicode PDF, and the codepage on the text is different from the codepage on the input spooled file. |
2022.M01 |
2022.M03 |
V7R2M0 |
||
Copy management results in missing data in PDF output. |
2022.M01 |
2022.M03 |
V7R2M0 |
||
Problem with copy management in back page overlays (duplex). Copy management and page control now works for dynamic backpages. |
2022.M01 |
2022.M02 |
V7R2M0 |
||
^JUR is now removed from non-unicode ZPL output, just like in the unicode counterpart. In very rare cases the ^JUR command could case extra empty labels to be printed, misalignment of the label gaps or even an error on the printer: Paper out. |
2022.M01 |
2022.M03 |
V7R2M0 |
||
Problem with Chinese text in PDF output. When an overlay has text constants in codepage 13488 (UCS2) it gives a wrong result in PDF. |
2022.M01 |
2022.M03 |
V7R2M0 |
||
Problem with ZPL with startpage > 1. When input spooled file has startpage > 1, a preview will show page 1 anyway, and concat lines does not work. |
2022.M01 |
2022.M03 |
V7R2M0 |
||
Copy management sometimes does not work for PDF output. |
2022.M01 |
2022.M03 |
V7R2M0 |
||
QR barcode with unicode numeric characters shows wrong result. |
2022.M01 |
2022.M02 |
V7R2M0 |
||
Spool variables in pdf-filenaming issue. Display file PNM357D - Data displayed do not always reflect content in the database. |
2022.M01 |
2022.M02 |
V7R2M0 |
||
Page management did not work in PDF when using copy management. |
2022.M01 |
2022.M02 |
V7R2M0 |
||
Maillog (web) now suppresses (TAB) and (SUB) from mailadresses and subjects. Remember to shutdown mailserver IF400MAILW before installing this PTF with : ENDTCPSVR SERVER(*HTTP) INSTANCE(IF400MAILW) |
2022.M01 |
2022.M02 |
V7R2M0 |
||
Allows larger datamatrix module size. |
2022.M01 |
2022.M02 |
V7R2M0 |
||
Barcode PDF417 had problems when input spooled file had code page different from the systems code page and you were using hex byte prefix on the font definition. |
2022.M01 |
2022.M02 |
V7R2M0 |
||
Expand RFID VDA5500 datarange. |
2022.M01 |
2022.M01 |
V7R2M0 |
||
Incorrect number of parameters, when restarting AFC700 job, caused by max number of profile handles in a single job. |
2022.M01 |
2022.M01 |
V7R2M0 |
||
Class path issue] reff: saxon Symptom - Error: java.lang.noclassdeffounderror: **.**.saxon.***.... |
2022.M01 |
2022.M01 |
V7R2M0 |
||
Various ActivationGroup/OVRDBF issues. |
2022.M01 |
2022.M01 |
V7R2M0 |
||
Output pdf-file from command TIFF2PDF is missing content on pages after 1st. |
2022.M01 |
2022.M01 |
V7R2M0 |
||
Page management did not work in PDF when using copy management. |
2022.M01 |
2022.M01 |
V7R2M0 |
||
Validation of alternate email routing. Error in Base64 handling and there's now a validation toggle on alternate routing. |
2022.M01 |
2022.M01 |
V7R2M0 |
||
XML+ 2 issues EMAIL --> Symptoms: 1) using Emal and XML+ together lead to CPYSPLF error. 2) Java exception regarding Saxon - class path error on |
2022.M01 |
2022.M01 |
V7R2M0 |
PTF number |
Description |
From version |
To version |
OS400 |
Module |
---|---|---|---|---|---|
ToolShed - does not start. Hard Java runtime exit in STRTOOLSS Changed: STRTOOLSS - now reports java runtime errors. - before errors suppresed. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Expand RFID VDA5500 datarange. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Conditioned overlay is missing in PDF when used in conection with copy management. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Error: java.lang.noclassdeffounderror: **.**.saxon.***.... |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Command TIFF2PDF missing content on pages after 1. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Tmp-Object locked during intensive PDF generation. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
XML+ Empty parameters on splf copy + Cummulative XML+ changes |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Validation of alternate email routing. Error in Base64 handling and there's now a validation toggle on alternate routing. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
PDF Concat permission issue |
2021.M01 |
2021.M07 |
V7R1M0 |
||
PDF Concat permission issue |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Additional conditions in concat are ignored. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Missing line in list of variables in PDF Filenaming, when viewing Keys and variables (8) in Page selections and document breaks (5). |
2021.M01 |
2021.M07 |
V7R1M0 |
||
When using *INPUT for line spacing on an overlay, the text is placed before the top margin. The error was introduced when support for duplex backpages in PDF was added. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Expand smtp user and password from 50 to 128. Use F22 on router, user and password fields to show popup dialog window with a 128 character field. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
In Code128 barcode | will be printed as is. In EAN128 / GS1-128 it will be printed as FNC1. This is the case for PCL and PDF. For label print, the change will be available in the 2022 versions. |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Expand table and buffers for certificates |
2021.M01 |
2021.M07 |
V7R1M0 |
||
RNQ1221 message from program APF700PDF (I/O operetion applied to closed file APFMSTP) |
2021.M01 |
2021.M07 |
V7R1M0 |
||
Wrong bufferlength in image HTTPS request |
2021.M01 |
2021.M06 |
V7R1M0 |
||
Permissions on files in import/export library are now set to *PUBLIC *ALL. |
2021.M01 |
2021.M06 |
V7R1M0 |
||
Special TTF issue: UCS2 char X'25AF' uses Glyph id 0. (Unknown char) |
2021.M01 |
2021.M06 |
V7R1M0 |
||
Checks JAVA_HOME on JNI calls |
2021.M01 |
2021.M06 |
V7R1M0 |
||
Stapling does not work after an InterForm400 upgrade. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Secondary attachment is not renamed in finishing definition in AFC. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Handling of Subject Alternative Name in IF400 SMTP. Check certificate now ignores Common Name in the certificate, because multiple domain names are now allowed in the extended Subject Alternative Name part of the certificate. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Enrich definition stops with RNQ0103: The target for a numeric operation is too small |
2021.M01 |
2021.M05 |
V7R1M0 |
||
QR barcodes: Problems related to the use of escape sequence to insert a special hex character. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Update certificate handling. |
2021.M01 |
2021.M05 |
V7R1M0 |
Advanced PDF |
|
XML+ Last Detail line not mapped. Problem: when using "Input line type" not blank in a "line type definition" only the first 100 spoolfile lines of the "Input line type" was processed. Fix: All Lines of the specified "Input line type" are now processed. |
2021.M01 |
2021.M05 |
V7R1M0 |
XML+ |
|
Monitor job AFCMONJOB stopped with an RNQ0121 array index error. This is solved with this PTF. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Keyboardtype AGE was not defined. That resulted in the device CCSID becoming -27, which caused an error in some screens. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Improved color handling in the PRTPDF command. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Wrong amount of parameters in call to a user exit program. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Solves a very seldom MSGW problem in the error MONITOR job in the Auto_form subsystem. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Setting environment variable JAVA_HOME now creates dtaara, APF3812/JAVA_HOME, if it is not existing. This solves a potential MSGW problem in TOOLSHED jobs after an upgrade of InterForm400. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Quality of imported jpg's not optimal. Alternative jpg import is now only activated, if the original import fails. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Missing data when copying AFPDS spooled file. In very rare situations some data can be lost when copying AFPDS spooled files to a physical file for a merge with an overlay. |
2021.M01 |
2021.M05 |
V7R1M0 |
||
Incorrect line spacing in InterWord400 |
2020.M13 |
2021.M05 |
V7R1M0 |
InterWord400 |
|
Install of some JPG images fails. Now InterForm400 force jpg's to be converted with the toolshed jobs to ensure that faulty JPG's are corrected and imported. |
2021.M01 |
2021.M02 |
V7R1M0 |
||
Error in pdf generation when signing large files Eg. 50000+ Pages. Possible errors in program APF3812/PDF310: "Procedure GEN, which ended in error." or "The target for a numeric operation is too small to hold the result" |
2021.M01 |
2021.M02 |
V7R1M0 |
||
The height of a QR barcode can be a bit to high when printing color PCL. |
2021.M01 |
2021.M02 |
V7R1M0 |
||
Error when updating alternate email gateway. When you add data and save, then only the host is saved. The rest of the fields are cleared. |
2021.M01 |
2021.M02 |
V7R1M0 |
||
F22 in the email configuration does not return full length of host or ip address. |
2021.M01 |
2021.M02 |
V7R1M0 |
||
When printing PCL &&IMAGE *PATHTIF is placed at the PCL margin to the right, if the orientation N, E, W or S is missing in the &&IMG line. |
2021.M01 |
2021.M02 |
V7R1M0 |
||
InterForm400 has become very slow. It is caused by a communication problem. |
2021.M01 |
2021.M01 |
V7R1M0 |
||
Fix for potential error: CPF22E6 Maximum number of Profile Handles have been generated. The message cause the AFC-job to end. We have made the Auto Forms Control job end and automatically start a new job when 12000 handles has been used. |
2021.M01 |
2021.M01 |
V7R1M0 |
||
Fix for error message: Decimal data error occured in program APF700PDF statement 244.80 |
2021.M01 |
2021.M01 |
V7R1M0 |
PTF number |
Description |
From version |
To version |
OS400 |
Module |
---|---|---|---|---|---|
Stapling does not work after an InterForm400 upgrade. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Handling of Subject Alternative Name in IF400 SMTP. Check certificate now ignores Common Name in the certificate, because multiple domain names are now allowed in the extended Subject Alternative Name part of the certificate. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
CEE0813 unmonitored. Allocate problem. CEE0813 unmonitored. The system has allocated temporary storrage without deallocating it afterwards. So after a period it could not allocate any more. After instaling the PTF please end subsystem AUTO_FORM and start it again. This will deallocate what was allocated before the PTF. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Update certificate handling. |
2020.M01 |
2020.M12 |
V6R1M0 |
Advanced PDF |
|
Linespacing incorrect in InterWord400. |
2020.M01 |
2020.M13 |
V6R1M0 |
InterWord400 |
|
IF400MAILW - Quotes in email adresses.Quotes in email adresses (instead of upgrade to M13) |
2020.M01 |
2020.M13 |
V6R1M0 |
||
A QR barcode with numeric content ended with a blank. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Monitor job AFCMONJOB may stop with an error. This is solved with this PTF. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Monitor job AFCMONJOB may stop with an error. This is solved with this PTF. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Missing data when copying afpds spooled file. In very rare situations some data can be lost when copying apfds spooled files to a physical file for merge with overlay. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Error in pdf generation when signing large files Eg. 50000+ Pages. Possible errors in program APF3812/PDF310: "Procedure GEN, which ended in error." or "The target for a numeric operation is too small to hold the result" |
2020.M01 |
2020.M13 |
V6R1M0 |
||
The heigth of a QR barcode can be a little too high when printing color PCL. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
After release update - start subsystem fails After release update the subsystem Auto_Form fails. Error starting STRTOOLSSS. (Will now fall back on default in no configurtion defined.) |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Using TrimLeft on a *Vx variable used in XML - fileNaming results in 1.Node/Att ribute value beeing "Corrupted". |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Enrich stops with RNQ0103 The target for a numeric operation is too small. |
2020.M01 |
2020.M10 |
V6R1M0 |
||
When having a SCS spooled file with X'1A' in it, You will get an error, if you try to merge it as unicode. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Prepare for email with unicode or DBCS input has p roblems when input lines are longer than 189 characters. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
Prepare for email with unicode or DBCS input has p roblems when input lines are longer than 189 characters. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
InterForm400 - Export leads to dump. A decimal data error when using "Option 3 = Copy resources used in already copied overlays" in the export menus. |
2020.M01 |
2020.M13 |
V6R1M0 |
||
When using &&IMG commands in input to PDF with TIFF files in compresion scheme CCITT Group 3 the program will end with an error in program IMG305MI. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
When a PCL job contains more than 223 different Ch inese, Korean or Japanese characters you will see wrong characters |
2020.M01 |
2020.M11 |
V6R1M0 |
||
Printing the overlay contents via F5=service does not include the Text Block lines. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
AFC job dumps with message MCH1210 from program APF7 14C at statement 3900.Fixed - More log - Wait on DataQue Max wait 1 sec. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
A QR barcode is printed in unicode PCL even if the c ondition in the remap window is not satisfied. the content of the barcode is all X'4040' |
2020.M01 |
2020.M11 |
V6R1M0 |
||
QR barcode is not printed in unicode PCL. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
In the PRTPDF cmd there has been the problem that text in color was printed wrong. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
Emailing: CC-information is not processed when excatly one CC- mail address is given - Note only occures for non *SCS print. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
In the PRTPDF cmd there has been the problem that text in color was printed wrong. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
Adding a new Mail Exitprogram Format, format 10, which contains attachment name. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
Modified Exit program handling XML+ Finishing-def. To better support X-Rechnung handling - the Exit program handling in XML+ module have been expanded. (Handling of XML-validation error adjusted.) |
2020.M01 |
2020.M11 |
V6R1M0 |
||
Parameter missing in PDF500C. The newest parameters (multiple attachments) are added. |
2020.M01 |
2020.M11 |
V6R1M0 |
ACA400 |
|
AFCSTART msgw, caused by missing jobq in STRTOOLSSS and IF400MAILS. STRTOOLSSS and IF400MAILS now correctly retrieves JOBQ and LIB from settings. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
AFCSTART msgw, caused by missing jobq in STRTOOLSS. STRTOOLSSS now correctly retrieves JOBQ and LIB from settings. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
An untraditonal soft font (widthin the TTF specification) resulta in message MCH0603 from program FNT465 stmt 4829.00. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
The TAB control character X'05' used in a *SCS spool ed file results in ad DSPLY 'Unknown data' It has been changed in the way that the TAB character is printed as a blank character. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
When printing PCL in color: BW images in conditioned overlays are not printed. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
When printing PCL in unicode, unicode characters could be printed as latin characters after a font change. |
2020.M01 |
2020.M11 |
V6R1M0 |
||
Special fix ! Only relevant for VANS users ( PEPPOL - Node acces point). |
2020.M01 |
2020.M11 |
V6R1M0 |
||
Barcode 3 of 9 in pdf is as long as it should if adjustment code is "B". |
2020.M01 |
2020.M11 |
V6R1M0 |
||
Prepare for email uses QGPL/QPRINT to produce a new spooled file. If QGPL/QPRINT has PRTTXT defined, it was used in the prepare.Now it has uses PRTTXT(*BLANK). |
2020.M01 |
2020.M10 |
V6R1M0 |
||
You get CPF2619 from program APF840. The table CP864424 does not exist. The problem was that the progran should have used table CP864420. |
2020.M01 |
2020.M10 |
V6R1M0 |
||
QR-barcode has been changed to use UTF8 instead of latin1. This has been done because the swiss payment standard does not accept latin1. |
2020.M01 |
2020.M09 |
V6R1M0 |
||
QR-barcode has been changed to use UTF8 instead of latin1. This has been done because the swiss payment standard does not accept latin1. |
2020.M01 |
2020.M09 |
V6R1M0 |
||
In PDF line distance is wrong, and with old behavior remaps in 180 degree are placed wrong. This PTF replace PTF 5624. |
2020.M01 |
2020.M09 |
V6R1M0 |
||
Program MAI730U gives a dump even if nothing is wrong. |
2020.M01 |
2020.M09 |
V6R1M0 |
||
'\x21' are normally not allowed in the RFID string, but are used to internally mark the end of the string. |
2020.M01 |
2020.M09 |
V6R1M0 |
||
When using the MLTARCVIEW command you get the message "I/O operation was applied to closed file APFRADP" from program APF700PCL. |
2020.M01 |
2020.M08 |
V6R1M0 |
||
Problem with encryption/exit pgm in PDF filenaming. Parameters are not passed in correct type to the exit program. |
2020.M01 |
2020.M08 |
V6R1M0 |
||
Problems when using "*INPUT" as parameters for Line spacing, Rotation and Font. |
2020.M01 |
2020.M08 |
V6R1M0 |
||
Problems with Swiss payment QR-barcode. Important: The Swiss Payment QR-barcode requires that you use a color or grayscale printer type. |
2020.M01 |
2020.M08 |
V6R1M0 |
||
In PCL a text constant is repeated instead of a new text constant, if the new constant does not have a CCSID. |
2020.M01 |
2020.M08 |
V6R1M0 |
||
InterForm400 has become very slow. It is caused by a communication problem. |
2020.M01 |
2020.M07 |
V6R1M0 |
||
Pointer not set for location referenced. |
2020.M01 |
2020.M07 |
V6R1M0 |
||
When making PDF-files with remaps in conditioned overlays, the remaps are not deactivated when the condition is no longer true. |
2020.M01 |
2020.M06 |
V6R1M0 |
||
When sending emails with the MRGSPLFPDF command the attached PDF-file gets the name "BLANKS". |
2020.M01 |
2020.M06 |
V6R1M0 |
||
You will get a "decimal data error" when using QR barcode in PDF. |
2020.M01 |
2020.M06 |
V6R1M0 |
||
Error message CPFA0B1 in BMP500C can occur when importing images. |
2020.M01 |
2020.M06 |
V6R1M0 |
||
in PDF and old behavior a block text can have wrong rotation. |
2020.M01 |
2020.M05 |
V6R1M0 |
||
First text constant is repeated a number of times. In PDF a text constant is repeated instead of a new text constant, if the new constant does not have a CCSID. |
2020.M01 |
2020.M05 |
V6R1M0 |
||
Decimal error when forwarding mail in WRKMAILLOG. |
2020.M01 |
2020.M05 |
V6R1M0 |
||
Text block is positioned wrong in PDF, if overlay rotation is not 0. |
2020.M01 |
2020.M05 |
V6R1M0 |
||
MRGSPLFPDF fails with error "Parameters do not match those in program PDF750C in APF3812." |
2020.M01 |
2020.M03
|
V6R1M0 |
||
When sending emails with attached pdf.file the neme of the attachment becomes "BLANKS". |
2020.M01 |
2020.M03
|
V6R1M0 |
||
An error can occur, when you are updating a PDF file naming page selection. The error occurs when you try to work with keys and variables. |
2020.M01 |
2020.M03
|
V6R1M0 |
||
An extra 1st page is printed in PCL when you are using the new textblock function in your overlay. |
2020.M01 |
2020.M03
|
V6R1M0 |
PTF number |
Description |
From version |
To version |
OS400 |
Module |
---|---|---|---|---|---|
Configuring email gateway are now saving data correctly. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
X'1A' instruction in spooled file results in error.When having a SCS spooled file with X'1A' in it, You will get an error, if you try to merge it as unicode. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Error in pgm MAI720 statement 6127.00. Error in program MAI720 statement 6127.00. Output to closed file. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Problem with Monroney in PDFA. When making a Monroney PDFA some text in conditioned overlays are misplaced. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Modified Exit program handling XML+ Finishing-def. To better support X-Rechnung handling - the Exit program handling in XML+ modul e have been expanded. (Handling of XML-validation error adjusted.) |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Source Examples for X-Rechnung handling. UPGRADE. To better support X-Rechnung handling - Example source offered in APISPC2SRC 1) XML - Exit program 2) Email - exit program |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Source Examples for X-Rechnung handling. To better support X-Rechnung handling - Example source offered in APISPCSRC 1) XML - Exit program 2) Email - exit program |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Modified Exit program handling XML+ Finishing-def.To better support X-Rechnung handling - the Exit program handling in XML+ module have been expanded. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Problem *INPUT for line spacing, rotation and font. We have seen problems when using "*INPUT" as parameters for Line spacing, Rotation and Font. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Problem related to TAB in unicode *SCS spooled files. The TAB control character X'05' used in a *SCS spooled file results in ad DSPLY 'Unknown data'. It has been changed so that the TAB character is printed as a blank character. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Lock operation for object USESTAP. Same as PTF 5481: Lock operation for object USESTAP, except this is for the 2019 Release. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Lock resource during PCL-Printing. Same as PTF5480 Lock resource during PCL-Printing, except this is for the 2019 Release. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
Problem in PCL with unicede characters. When printing PCL in unicode, unicode characters could be printed as latin characters after a font change. |
2019.M01 |
2019.M06 |
V6R1M0 |
||
QR-barcode now uses UTF8. QR-barcode now uses UTF8 instesd of latin1. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
PDF wrong placement ramaps 180 degree. In PDF old behavior remap windows with rotation 180 degree are placed wrong. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Problems with Swiss payment QR-barcode. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Problems with Swiss payment QR-barcode. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
&&IMG *COLOR image is not printed in PCL. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
No XML-Document generated. XML+ No Xml document generated - no errors found in log files. |
2019.M01 |
2019.M600 |
V6R1M0 |
||
Data matrix barcode prints a barcode on next page. Data matrix barcode can print the last part of a data matrix barcode on an extra page when it is the last part of the last page. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Could not see which product was unlicensed. When a AUTO_FORM job is in a message wait with a licence problem you could not see which function that was running in the joblog or QSYSOPR message queue. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Problem with extreme TIF CCITT.T6 compresion. Problem extreme TIF CCITT.T6 compresion. The problem was caused by that file had a content, with a lot of dust. That gave the situation, that the file became 60% bigger than the same content without any compression. We have not seen that situation before. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Problem with extreme TIF CCITT.6 compresionT. Problem extreme TIF CCITT.T6 compresion. The problem was caused by that file had a content, with a lot of dust. That gave the situation, that the file became 60% bigger than the same content without any compression. We have not seen that situation before. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Problem with export when library APFEXPORT does not exist. If you have an export library with a name other than APFEXPORT you can now complete the export without problems even if library APFEXPORT does not exist. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
MAI720 Exit program format 7 fixed. Exit format 7 has been adjusted back to 55 parameters. |
2019.M01 |
2019.M999 |
V6R1M0 |
||
Problems with TIFF files with LZW compression. We have seen problems with TIFF files with LZW compresion. Besides of that, we have opened for extention .TIFF when installing tiff files as B/W images. Up till now only extention .TIF has been accepted. This PTF replaces PTF5531. Program IMG316MI was missing in PTF5531 |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Problems with deleting an export distribution. When deleting an export distribution, you get a screen about target version. This has been removed. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Blanks now allowed in VDA5500 RFID tags. There were a problem with blanks in VDA5500 RFID tags, that caused errors in the length calculation. |
2019.M01 |
2019.M05 |
V6R1M0 |
||
Error in ZUGFeRD-XML-Creation with Emailing.Bug fix. 2019 Version. |
2019.M01 |
2019.M999 |
V6R1M0 |
||
Naming exit program recieved only 10 parameters.File naming user exit program sends only 10 parameters in exit format 2 and 3. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Naming exit program recieved only 10 parameters. File naming user exit program sends only 10 parameters in exit format 2 and 3. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
InterVANS CSC changes to EHF deliveries to Norway. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Unicode emails without subject gets a subject of all the unicode character U'4040'. That is a chinese character. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Concat lines in unicode PDF that does not find anything results in the character for unknown glyph. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Decimal data error occured in program APF700PDF statement 104930. The problems occurs when an InterWord spooled file comtatins an .IMG command. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
SSL support for &&IMG HTTP request. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Barcode Code128 shows [ instead of $ for codepage 870/1153.Barcode code128 in both PCL and PDF replaces $ with [ when running codepage 870 or 1153. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Some characters in a PCL soft font are missing the width in the APFTBR file after the font has been imported. That results in a bad result when rigth or center adjust of text. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Decimal data error statement 762.90 pgm APF700PCL. Program APF700PCL goes into a decimal date area in statement 762.00 when a selector finds an overlay with *INPUT in rotation and the input spooled file is in InterWord format. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Could not use a TIFF image.There was a problem in program IMG314MI when trying to install a TIFF image or use it with a &&IMG comand line in print. The problem was caused by an image line which in compressed form used more than 2000 bytes. This area has been extended to 4000 bytes. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Export version is incorrect. Export version 2018-2015 is marked 2018, and should be 2015. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Naming exit program recieved only 10 parameters. File naming user exit program sends only 10 parameters in exit format 2 and 3. |
2019.M01 |
2019.M03 |
V6R1M0 |
||
Enhance XML+ with template invoicing. Enhance XML+ with template invoicing. EHF 3.0 support has been added. |
2019.M01 |
2019.M601 |
V6R1M0 |
||
SMTP router are not saved or blank, when exiting the configuration page. |
2019.M01 |
2019.M02 |
V6R1M0 |
||
Enhance XML+ with template invoicing. Enhance XML+ with template invoicing. Zugfered 2.0 and OIOUBL 2.0 support. |
2019.M01 |
2019.M601 |
V6R1M0 |
||
InterXML + "Out of memory". java/lang/OutOfMemoryError Default JVM changed to 64 bit. |
2019.M01 |
2019.M02 |
V6R1M0 |
||
&&IMG *PATHANY fails if image in overlay. When using a &&IMG *PATHANY together with an overlay that has an image in it, program APF700PCL or program APF700PCLU fails. |
2019.M01 |
2019.M02 |
V6R1M0 |
||
There was a codepage problem on ZPL labels with a RFID tag. The problem starts on page 2. APF700PCL or program APF700PCLU fails. |
2019.M01 |
2019.M02 |
V6R1M0 |